IM U9310010 TST-11 LCD touchscreen programmable thermostat Aug 2014
TST-11 PROGRAMMABLE TOUCHSCREEN THERMOSTAT U9310010 LCD Symbols Configuration Menu
Setting the clock and day of the weekSelect the required operating modeThis thermostat is fitted with a real time clock. It is essential that the clock time and day are set accurately if you require1) Touch time display .Auto – Automatic mode, the thermostat executes the preprogrammed schedules. To adjust these schedules, see page 2 the program sIn addition to Automatic mode, this thermostat has 3 extra manual modes, i.e , each of these manual m – Comfort temperature mode, the highest temperature you want to achieve, this is the temperature that will be required when th – Economy temperature mode, the lowest temperature, the temperature you want to go no lower than when the room is not in use. – Vacation temperature mode, this is set to stop your floor from going below the set temperature. Default is 10 °C. To change the set temperatures, touch temperature display. Use or to adjust to the required temperature.See overleaf for further setting up information2) Touch day display .Use or to change the time. Press and hold
Use or to change the day. Touch to store and exit.(or touch Day display to cancel and exit). or to change the time faster. Touch to store and exit( or touch time display to cancel and exit).
The buttons are lockedTurning on/off the thermostatHeating is turned on
Automatic mode, executes the programmed schedulesThe sensor is not being read by the thermostatErrTemporary temperature overrideFrost protection activatedRoom temperatureRTAUTOFloor temperatureFT
O / RIDESymbols
The program numberDay of the week. Day 1= Monday, Day 2= Tuesday… etc.Reminding the user to connect the floor sensor (AF and F model only)Touch to view floor temperature for 5 seconds (AF model only)Touch to switch among Auto Touch to start programming of your thermostatComfort temperature modeEconomy temperature modeDayProgram 1,2,3,4,5,6Vacation temperature mode
SymbolsDescriptionDescription
This thermostat is a combination model allowing you to choose among 3 models. A model: air only, with built in sensorAF model: air & floor, with both built in and remote sensorF model: floor only, with remote sensorMenu #01Model selectionSwitching differential02Features descriptionFeatures Explanation
A, AF, FTouch or to adjust06Temperature format07C / F This allows users to select between °C or °F. 24H / 12H ( 24 hour clock by default )0812 Hour or 24 Hour clock format selection 030 °C by default, -5°C ~ +5°C Calibrate the room temperatureTo compensate for any difference between the displayed room temperature and a thermometer040 °C by default, -5°C ~ +5°C
SetSchedule
HeatingMode
Done
Done
Done
Then you will see menu 01. Touch or to select the menu number. Use or adjust the settings.Touch to accept and store.
Previous
Done
Next
The numbers of degree difference before switching. The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature.With a 2°C differential, the heating will switch on 1°C below the set temperature and switch off 1°C above the set temperature. 1 °C, 2 °C, …10°C, 1°C by defaultMaximum floor temperature0540 °C by default, setting range 20°C ~ 40°C This is to protect the floor surface by limit the floor temp. ( AF model only) 1211 Program type selectiontouch to turn thermostat off, and now touch
Set Menu
To enter into menu settings,page 1
out, home,sleep) and 2 days(Saturday and Sunday) with the same six events.
Set backlight turning-on time. This feature is to ensure that the required temperature hasPump protection(hydronic heating only)
Save money by setting program schedulesThis thermostat can be individual 7-day programmable. For each day of the week you are able to have 6 timed set temperature schedules.Above are default program schedules, to make changes, follow easy steps as below. This product should be installedby a qualified
Carefully separate the front half of the thermostat from the back plate by placing a small flat headterminal driver into the slots on the bottom face ofthe thermostat
1
Carefully unplug the ribbon connector which is plugged in to the front half ofthe thermostat
2Place the thermostat front half somewheresafe. Terminate the thermostat as shown in the diagrams below
3Screw the thermostat backplate on to the back box
4Re-connect the thermostat ribbon cable
5
Installation and WiringPress , you will see day display flashing. Use or adjust the day to the day you wish to start programming Press , the LCD will show program 1 with the time display flashing. Use or adjust the time you wish the program 1 event to commence Press , the LCD will show a temperature value flashing. Use or set the desired heating temperature to be maintained for Press , now the LCD will show program 2 with the time display Repeat step 4,5,6 to set remaining programs. Press to store and exit. During setting programs, press (if visible) will clear a program entry1.2.3.4.5.5.6.6.7.8.
(Press to select all days of the week, to cancel selecting all days of DONE
DONE
All Days
All Days
SetSchedule
Temporary Temperature OverrideTouch the temperature display, and it will start to flash. Use or to adjust. Press to accept, and you will see O/RIDE on LCD. Thermostat will maintain the new set temperature until the next programmed event(comfort level). To cancel the override setting, press Lock the KeypadTo lock the keypad, press and hold the bottom left corner ofdisplay for 5 seconds, you will see a lock symbol . Reset to Factory SettingsWith thermostat turned off, press and hold the up left cornerof display for 5 seconds until you can see RESET on LCD.
To unlock, repeat the steps above.
DONE
RunSchedule
Next
Next
Next
Next
Next
Next
Delete
until the beginning of the next program. Note: It is faster to program the same schedule for the entire week and then to adjust the exceptional days. Set time and temperature for the next time period(Leave). Repeat steps 2 and 3for each time period of the weekday.In 7 day program modeIn 5_2 day program modeIn 6_1 day program mode, follow same steps as 5_2 modeNOTE:
flashing, signifying the second daily event is now being programmed. the program 1 event.for the currently selected day or days.or to the day you wish to edit an existing event or program.Press , you will see the time flashing. Press to move to the weekend(sat-sun) time periods settings. Use or to set your weekday Wake time(Mon-Fri), then press1.2.3.4.
Use or to set the temperature for this time period, then press
SetSchedule
Press to save and exit.Day 1 – 5, refers to the weekday( Monday to Friday)Day 6 – 7, refers to the weekend( Saturday and Sunday)and thermostat will maintain the temperature setpoint of the last executed programelectrician.
page 2TST-11 PROGRAMMABLE TOUCHSCREEN THERMOSTAT U9310010
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DWTel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.ukProgrammeStart timeSetpoint
106:3021°C208:3016°C311:3016°C413:0016°C516:3021°C622:3016°C 1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET Wiring Regulations.2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles.3. Before commencing work on the installation, the electricity supply must be disconnected.4. The depth of the back box should be 35mm minimum.
WARNING
123456SWL SensorRemoteout usedLNot230V ACN
~
~