IM U9310044 CS-11 7 day programmable digital LCD thermostat Aug 2014

IM U9310044 CS-11 7 day programmable digital LCD thermostat Aug 2014

See overleaf for further setting up informationSensor selection. This thermostat is a combination model allowing you to choosebetween 4 different models. (A, AF,F )A model: air only, with built in sensorAF model: air & floor, with both built in and remote sensorF model: floor only, with remote sensorConfiguration MenuTurning ON/OFF Your ThermostatPress buttton to turn the thermostat ON or OFF. When thermostat is turned off, LCD will display OFF. This thermostat is full of useful features which can be set quite easily through the feature configuration menu. To access the feature configuration menu, simply turn off your thermostat
and hold button M for 5 seconds. Now you can see Menu 1, to proeceed to other menu, press button M again. To exit menu, press buttonMenu # 1Switching differential.Calibrate the room temperature. This feature is used to compensate for any differenceCalibrate the floor temperature. This feature is used to compensate for any differenceSet the floor temperature limit.Set backlight turning-on time. Selecting on will turn the light on continuously.Selecting off will turn the light off. Selecting 20 seconds will turn the light on for 20 seconds.Select temperature format Optimum start(preheat). This feature is to ensure that the required temperature hasalready been reached when you get up in the morning or come home from work.Select 12 / 24 hour clock24 12 / 24 Pump protection(for hydronic heating only). In hydronic heating installations, it is recommended to activate the pump at least 15 seconds every 24 hours in order toavoid any seizing. Select ON to activate this feature, OFF to deactivate. When thethermostat is activating the pump, the icon will blink.23456789101112Feature DescriptionFactory DefaultFeature Value
0°COFFON / OFFON / OFF OFF7_05_2 / 6_1 / 7_0OFFON / OFF40 °C20°C ~ 40 °C 20 seconds 20 seconds / ON /OFF °C / °F °C
A / AF / F A Press or to selectThis product should be installed by a qualified electrician.
The number of degrees difference between switching off at the between the displayed room temperature and a thermometer. between the displayed floor temperature and a thermometer. This feature is to protect the floor surface. °C or °F. Buttons and LCD displayButtonsShort press �Press 5 secondsTurning on/off thermostatMenu button( when thermostat is turned off) Auto/Manual mode selectionIncrease the set valueBring up vacation modeCheck floor temperature (AF model only)Decrease the set valueLock /unlock buttonsReset to factory settings(when thermostat is turned off) ++Set the time and week daysCancel override( when in override mode)Confirm settings
M
M
The buttons are locked.Displays when heating is active
SymbolDescriptionAuto mode(use button M to select)Manual mode(use button M to select)Vacation modeTemporary temperature overrideFrost protection activatedSet temperatureThe program numberProgram 1,2, 3,4,5,6
AUTOSET AT
Program type selection.This gives user 3 options of program type. 5_2 will give you 5 days(Monday to Fiday) with the same six events(Wakeup, out, home,6_1 will give you 6 days(Monday to Saturday) with the same six events(Wakeup, out, home,7_0 will give you individual settings for each day from Monday to Sunday.out, home,sleep) and 2 days(Saturday and Sunday) with the same six events.out,home,sleep) and 1 day(Sunday) with the same six events.Frost protection.This feature is to avoid room temperature going below 5°C E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance.E1 = The remote floor sensor has not been connected, has been wired incorrectly or the probe is faulty.LO = The room or floor temperature is below 0ErrorMessage°C HI = The room or floor temperature is above 50°C Program button
means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and switch off 1°C above the set temperature. 1°C1°C ~ 5°C-5°C ~ +5°C0°C-5°C ~ +5°C
CS-11 LCD 7-Day 5+2 Programmable Digital ThermostatU9310044
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DWTel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk
Temporaryset temperature and on again to reach the set temperature.The default is 1°C which
To temporary override the current set temperature,1. Press up or down button once, the set temperature starts flashing 2. Press up or down button again until the temperature you want is displayed 3. Press to confirm the setting with shown on LCD Now your thermostat will override the current programming and maintain the new set and hold button for 5 seconds until disappears.Press button M to select Auto/Manual mode. In Manual mode, the thermostat maintains a constant set temperature manually set by the user. In Auto mode, the thermostat executes the preprogrammed schedules.To adjust these schedules, follow the easy steps below,To set vacation mode press and hold the up button for 5 seconds until appears. Usesame procedure to exit this mode.Vacation mode up or down button to change the set point and wait for 5 will maintain a set temperature(default
Your thermostat has the ability to reset all settings to the factory defaults. If you arecertain you want to do this: In standby mode(when thermostat is turned off), press
If thermostat is set in AF model, press and hold the down button for 5 seconds, floor temperature will show and it will automatically revert back to room temperature This a
Installation and Wiring
86mmmm68
Ra iew
45mm
13mm
27 mm26 mmSide View
60mmmm6886mm4mmmm7LLLOAD(16A)FEED(220VAC+/-15%)Floor Sensor(or remote air sensor)NN
To lock the buttons, press and hold the up and down buttons for 5 seconds until yousee a lock icon appearing, to unlock, repeat the steps above. and hold button M and for 5 seconds until “RES” is shown for 5 seconds on LCD.This thermostat is fitted with a real time clock. It is essential that the clock time and day are set accurately if you require your programmed events to start on time. Follow the Set the Time and Day
Auto / Manual Mode
Program your thermostat
Resetting factory defaults
Lock the buttons
View floor temperature
Temporary temperature override
Vacation mode
Press the button onceUse up or down button to change the time (Hold up or down button to changePress button again, the day of the week will flash Press button again to accept and exitUse up or down button to change the day of the week
Press and hold button M for 5 seconds until “Program” is shown with the Day flashing. Use up or down button adjust the day (hold up or down button for 5 seconds to set all days the same). Press button M again and use up or down button to set the desired temperature to be Press button M to bring up the program 1. Use up or down button to set the start time To skip program 2 ,3,4,5 for Saturday and Sunday, simply adjust the set temperature for program To skip program 3 and 4, simply adjust the set temperature for program 3 and 4 to the same set temperature as program 2. 2 ,3,4,5 to the same set temperature as program 1.
and the time will flash Step 1.Step 2.Step 3.Step 4.Step 5.10°C) all the time. Press
Carefully separate the front half of the thermostat from the back plate by placing a small flat headterminal driver into the slots on the bottom face ofthe thermostat
1
1
2
3Carefully unplug the ribbon connectorthe thermostat
2Place the thermostat front half somewheresafe. Terminate the thermostat as shown in the diagrams below
3Screw the thermostat backplate on to the back box
4Re-connect the thermostat ribbon cable
5
(default 06:30).(Hold up or down button to change by 15 minutes each time.)ProgrammeStart timeSetpointmaintained for program 1.(default 21 °C) below easy steps, by 15 minutes each time.)seconds to accept and exit.
temperature until the next program period begins. To cancel the override setting, pressin 5 seconds. CS-11 LCD 7-Day 5+2 Programmable Digital Thermostat
U9310044
Wiring Diagram
123456SWL SensorRemoteout usedLNot230V ACN
~
~
Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DWTel: 01993 824900 : www.emmeti.co.uk : e: sales@emmeti.co.uk
“ Temporary ” “ Temporary ”
Repeat and unitl you finish the settings for 6 programmes. Press button M to accept and exit. The below is the default factory settings for the 6 programmes.
2
3
1234606:3008:3011:3013:0016:3022:3021°C16°C16°C16°C21°C16°CNote: It is faster to program the same schedule for the entire week and then to adjust the exceptional days. 1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote senso Wiring Regulations.2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the cu3. Before commencing work on the installation, the electricity supply must be disconnected.
WARNING
Dimensions

IM U9310044 CS-11 7 day programmable digital LCD thermostat Aug 2014 Ranges