Wireless Controls

Emmeti wireless heating control systems offer a solution for UFH or radiator zone control. The range of products including wiring centres, sensors, programmable and dial operated thermostats. The system is suitable for domestic or commercial applications.

Please note that the range of wireless controls included in this pricelist are not compatible with the range in our previous price catalogues (2011 and prior). To distinguish between the two ranges the new controls are prefixed with ‘N’.

Technical Data

02018110

N CTA W Programmable thermostat

  • Extra-large, backlit LCD display
  • Battery operated with battery life in excess of 2.5 years
  • 7 day programming with built-in or end user programming
  • Up to four on-off time periods per day
  • Combined air and floor temperature limit function using remote sensor
  • Frost protection and holiday mode functions
  • Simple dial operation for comfort and setback temperatures

For further technical details, installation requirements and wiring connections please refer to the ‘downloads’ section below.

02018112

N TA W Thermostat

  • Simple dial operation for ease of use
  • Battery operated with battery life in excess of 2.5 years
  • Range limiting using plastic pins at the rear of the dial
  • Night setback operation scheduled using the wiring centres in the range
  • Heating or cooling selectable either at the thermostat or at the wiring centre
  • Can be used with remote sensor for use in bathrooms

For further technical details, installation requirements and wiring connections please refer to the ‘downloads’ section below.

U9132155

N ETA W Digital Wireless Thermostat

  • Wireless battery operated digital thermostat with blue back-lit LCD display
  • This unit can operate to control both heating and cooling and has temperature range limitation.
  • The remotely located thermostat will signal the N AR W receivers connected to the 2- or 8-channel wiring centres
  • Night set back (NSB) facility is available via the wiring centre
  • Available with remote sensor options

For further technical details, installation requirements and wiring connections please refer to the ‘downloads’ section below.

02018114

N AR W Receiving antenna

  • Used with the two and eight channel wiring centres and supplied with a 5m cable
  • Can be used as a repeater where the building construction or the size of the building prevents or interferes with wireless transmission
  • One antenna can be used with up to 10 wiring centres using the interconnection cable supplied with the 8 way wiring centres.

For further technical and installation details please refer to the ‘downloads’ section below.

 28130662

Remote Sensors

  • Extends the flexibility of the N TA W and N CTA W thermostats by allowing remote temperature sensing
  • Cased version allows connection using standard 1.5mm2 flat cable.
  • Can be used in bathrooms or for tamper resistant applications
  • Uncased, 1.5m lead version can be used for built-in applications or for combined air/floor sensing with N CTA W programmable thermostat

For further technical and installation details please refer to the ‘downloads’ section below.

Downloads

Information

Emmeti Underfloor Heating Manifolds Sales Brochure

Product and system guide with range information, product features and examples for Under Floor Heating applications

Declaration of Conformity - Dir. 2014/53/UE (RED - Radio Emitting Devices)

Emmeti Pricelist_2017_Zone Controls_Wireless Controls

Technical


Installation Guide N AR W Receiving Antenna May 2012

Installation Guide with wiring diagram for N AR W Receiving Antenna

Installation Guide N CTA W Programmable Thermostat May 2012

Installation Guide with operating instructions and wiring diagram for N CTA W Programmable Thermostat

Installation Guide N MC2 W 2 Channel Wiring Centre May 2012

Installation Guide with operating instructions and wiring diagram for N MC2 W 2-Channel Wiring Centre

Installation Guide N MC8 W 8 Channel Wiring Centre May 2012

Installation Guide with operating instructions and wiring diagram for N MC8W 8-Channel Wiring Centre

Installation Guide N R1 W 1 Channel Wiring Centre and Receiver May 2012

Installation Guide with operating instructions and wiring diagram for N R1 W 1-Channel wiring centre and receiver

Installation Guide N TA W Thermostat May 2012

Installation Guide with operating instructions and wiring diagram for N TA W Thermostat

Technical Product Guide wireless zone controls July 2016

Technical Guide covering product features, technical specification, wiring diagrams and dimensional drawings for a range of wireless thermostats, sensors, and wiring centres

IM-N-ETA-W-Digital Wireless Thermostat

Wireless digital thermostat installation guide

Wireless Controls Technical Product Sheet July 2016

Wireless Controls Pairing Procedures for N MC2 W 2-channel wiring centre, N MC8 W 8-channel wiring centre, and N R1 W Single Channel. Associating thermostats with programmable thermostats

FAQS

What alternative is there for a 1-channel wireless centre?
A 2-channel wiring centre and a receiving antenna.  As these are wireless controls, they must be used with the wireless thermostats and/or programmable thermostats.  For full range of wireless controls please click here.

What size wiring / cable do I need for connecting thermostats to an Emmeti EWC wiring centre as part of an underfloor heating system?
Cable Sizing must be carried out by a qualified electrician. In general, 1mm2 twin and earth cable is sufficient, flexible cable to and from the wiring centre should be no less than 0.75mm2