TPG EWC-1 and EWC-2 wiring-centre May 2014

TPG EWC-1 and EWC-2 wiring-centre May 2014

1
A wiring centre range with built in isolating switch allows access to thermostats and actuators
safely, without isolating the whole electrical circuit. The status of system zones can be seen
immediately, with call for heat LED lights on the front face of the centre. A power, boiler and
e facility to connect up to �ve
actuators per zone. Fully integrated earth connection, which will facilitate all earth connections to
ensure earth continuity .
EWC-1 Wiring Centres
-1 is now available. The

ays, 8 zone and 12 zone models.
Includes a fully integrated earth connection, which will facilitate all earth connections to ensure
earth continuity. Incorporates boiler/pump on LED to identify when the system is calling for heat.
allow night set back operation for
use with compatible thermostats
EWC-2 Wiring Centres
Technical Product Guide
For more information please call us on
01993 824900
or view our website at
www.emmeti.co.uk
EWC Wiring Centres
2
EWC-1 Hard-wired wiring centres with on-off switch
230V and 24V 8-way wiring centres specially designed for radiant heating and cooling
applications
adding new thermostats or electrothermic heads to the
the whole electrical system
with a single time switch
Earth continuity terminals are integrated as standard, to
facilitate earthing requirements of system components to be
connected to the wiring centre
simple to connect a manifold pump to the centre
Separate boiler interlock terminals enable the boiler to be �red
The status of the system can be monitored with the LED’s on

almost all hardwired applications for both radiant heating and cooling.
Why you should choose Emmeti EWC-1 Wiring Centres
A
J
I
G
C
B
E
D
F A:On/ Switch B: Protecve Shield for Power in and Opona Progammer Terminas C: Eath Bar D Pump Output(230V) E: Boile Interlock (Volt free) F: 8 Channels to Accommodate Termostat and Actuator Wiring G: LEDZone on IndicatorsH Boile On LEDI: Pump On LED J: Power On LED
H
A
K
J
H
D
B
F
E
G
I
C
L
A:On/ Switch B: Man Live andeutra Terminas C: Opona Externa Progammer Terminal D Eath Bar E: Pump Output(230V) F: Boile Interlock (Volt free) G: 8 Channels to Accommodate Termostat and Actuator Wiring H: LEDZone on Indicators I: Boile On LED J: Pump On LED K: Power On LED L: 230V to 24V Trasformer

Wiri
EWC-1 230V 8 Way Wiring Centre
EWC-1 24V 8 Way Wiring Centre
A
J
I
G
C
B
E
D
F
A:On/ Switch B: Protecve Shield for Power in and Opona Progammer Terminas C: Eath Bar D Pump Output(230V) E: Boile Interlock (Volt free) F: 8 Channels to Accommodate Termostat and Actuator Wiring G: LEDZone on IndicatorsH Boile On LEDI: Pump On LED J: Power On LED
H
A
K
J
H
D
B
F
E
G
I
C
LA:On/ Switch B: Man Live andeutra Terminas C: Opona Externa Progammer Terminal D Eath Bar E: Pump Output(230V) F: Boile Interlock (Volt free) G: 8 Channels to Accommodate Termostat and Actuator Wiring H: LEDZone on Indicators I: Boile On LED J: Pump On LED K: Power On LED L: 230V to 24V Trasformer

Wiri
3
EWC-2 Hard-wired wiring centres
230v 8-way & 12-way wiring centres specially designed for radiant heating and cooling
applications
single timeswitch
catered for
Earth continuity terminals are integrated as standard, to
facilitate earthing requirements of system components to
be connected to the wiring centre
it simple to connect a manifold pump to the centre
Why you should choose Emmeti EWC-2 Wiring Centres

satisfy almost all hardwired applications for both radiant
heating and cooling.
EWC2 Wiring Centre8 and 12 Way Option8 way
12 way
A: On LED B: Boiler/Pump LEDC: Power Supply Terminal L and ND: Optional External Control TerminalsE: Pump Output TerminalsF: Boiler Interlock TerminalsG: Fuse (8amp fast blow)H: 12 Thermostat and Actuator ChannelsI: Earth TerminalsA: On LEDB: Boiler/Pump LEDC: Power Supply Terminal L and ND: Optional External Control TerminalsE: Pump Output TerminalsF: Boiler Interlock TerminalsG: Fuse (8amp fast blow)H: 8 Thermostat and Actuator ChannelsI: Earth Terminals
EWC- 2 230V 8-way wiring centre
EWC- 2 230v 12-way wiring centre
4
Technical Data
On 24V models, note that when a 230V timeswitch is connected to the wiring centre, the wiring centre switch will not isolate
There is a 2.5 minute time delay following a call for heat before the pump is energised
Wiring centres feature independent boiler and pump interlock relays,
8 zone connections (with loose terminal connections to enable up to
�ve actuators to connect to each zone), on-off switch to enable safe
working inside the wiring centre and to thermostat and actuator
connections. Each circuit has an LED call for heat indicator. The
centre includes connections for an external timeswitch to allow
night set back operation for suitable thermostats, and includes a fully
integrated earth connection.
The 24V version incorporates a 50VA transformer with capacity for
up to 15 x 3W actuators. Both versions offer IP44 protection to
enable siting inside a manifold cabinet.
* Additional loose cap terminals can be obtained, code U9360030.
EWC-1 Hard-wired wiring centres with on-off switch
Size Pcs./Pack Code
230V 8-way wiring centre with on-off
24V 8-way wiring centre with on-off
Model:
230V EWC-1 Wiring Centre
24V EWC-1 Wiring Centre

Humidity limits
Enclosure rating
Wiring Centre Outputs :
Maximum electrical load:
EWC-1 Hard-wired wiring centres with on-off switch
(continued)
5
Technical Data
A more commercially priced option, the EWC-2 230v Wiring centres
feature boiler and pump interlock relays, 8 zone and 12 zone
connections. Includes a fully integrated earth connection, for fast
and easy installation of pump or other earthed equipment.
Incorporates a single interlock LED call for heat indicator for both the
boiler and pump and also a power on LED.
The centre includes connections for an external time switch to allow
night set back operation for suitable thermostats.
EWC-2 Hard-wired wiring centres
Size Pcs./Pack Code
230V 8-way wiring centre
230V 12-way wiring centre
EWC-2 Hard-wired wiring centres
(continued)
Model:
230V EWC-2 8 Way
230V EWC-2 12 Way
Humidity limits
Enclosure rating
Thermostat and actuator connection chan
*
*
Wiring Centre Outputs :
Maximum electrical load:
6
1. NSB = Night Set Back Connection (if required)
2. SWL > = Switched Live back from stat
3. SWL < = Switched Live to external control (if required)
4. TN = Neutral to thermostat
5. TL = Live to thermostat
6. L1 = Live to Electro-thermic actuator head
7. N1 = Neutral to Electro-thermic actuator head
Zone terminal identification
EWC-1 and EWC-2 Hard-wired wiring centres
ACTUATOR THERMOTAT NLCSWLNSBSWLSWLNSBSWLSWLNSBM230V~TIMERPUMP230V~BOILER24V~24V~THERMOSTAT 24V~ACTUATOR 24V~FUSEFUSE F2 4A24V~OFF50H230V~ ±10%NLETIMERM24V~NSSWLL1N1L2NAN2TNTLL1N1TNTLL1N1TNTLTNF18AON L1N1
ACTUATOR 230V~ ±10%L
NTHERMOSTAT
NL
CSWLNSBSWL
SWL
NSBSWL
N
SWLNSB
M
230V~TIMER
PUMP230V~
BOILER*230V~230V~THERMOSTAT230V~ACTUATOR 230V~
FUSEOFF
50Hz
E
2L2NATNTLL1N1TNTLL1N1L1N1ON F18ATNTLTNTL
Wiring diagram to suit EWC-1 and EWC-2 230v versions
1
1
7
ACTUATOR THERMOTAT
NL
CSWLNSBSWL
SWL
NSBSWL
SWLNSB
M
230V~TIMER
PUMP230V~
BOILER24V~24V~THERMOSTAT 24V~ACTUATOR 24V~
FUSE
FUSE F2 4A
24V~
OFF
50H
230V~ ±10%NL
E
TIMER
M24V~
NSSWL
L1N1L2NAN2TNTLL1N1TNTLL1N1TNTLTNTLF18AON L1N1
ACTUATOR 230V~ ±10%LNTHERMOSTATNLCSWLNSBSWLSWLNSBSWLNSWLNSBM230V~TIMERPUMP230V~BOILER*230V~230V~THERMOSTAT230V~ACTUATOR 230V~FUSEOFF50HzE2L2NATNTLL1N1TNTLL1N1L1N1ON F1TNTLTNTL
Wiring Diagram to suit U9360020 EWC-1 24v 8-way wiring centre.
and terminal NA.
ACTUATOR 1
L1
NL
NOC
SWLNSBSWL
TLTN
N1
L2N2
SWLN1NSB
L1
PUMP230V~
BOILER230V
FUSEF18A
50Hz230V~ ±10%NLE
EMMETI EWC-2 230V WIRING CENTRE SHOWING CONNECTIONS TO CS-11 PROGRAMMABLE THERMOSTAT U9310040
Main IsolatorFuse
N
TL234561CS- 11 programmable thermostats
INTERNAL RELAYS FOR PUMP (230V) & BOILER (VOLT FREE)REMOTE SENSOR (IF REQUIRED)
Note: To provide a 230V output to boiler please link L2 to NO as shown.
Wiring diagram to suit EWC-1 and EWC-2 230v versions showing connections to
Emmeti’s CS-11 range of programmable thermostats
EWC-1 and EWC-2 Hard-wired wiring centre
Technical Product Guide
For more information please call us on
01993 824900
or view our website at
www.emmeti.co.uk
EWC Wiring Centres
Technical Product Guide
For more information please call us on
01993 824900
or view our website at
www.emmeti.co.uk
EWC Wiring Centres

TPG EWC-1 and EWC-2 wiring-centre May 2014 Ranges